Green Star Technical Clarification Rulings
Technical Clarifications for Green Star represent our answers to Technical Questions submitted by projects, and provide further guidance and reference to others. The list is regularly updated.
There are two types of Technical Clarifications listed in the table below:
General Clarifications
These are extensions to the guidance provided in the Submission Guidelines. They clarify and sometimes supersede the original Credit Criteria or
Compliance Requirements. General Clarifications set precedent for future project teams to follow. Should a project team wish to apply a general clarification to its project, there is no requirement for further Technical Questions to be submitted. NZGBC Assessors will also use them as precedents to assess submissions.
Project Specific Clarifications
These are published as references for other projects but, unlike General Clarifications, they do not set precedent. They often relate to special
situations where multiple prerequisites exist for a particular project and are less likely to reoccur to another project. Therefore, rulings set for Project Specific Clarifications are often conditional and will likely vary for other projects. Each project still needs to submit its own Technical Questions and provides evidence relating to its own building in order to have a similar ruling approved for that specific building.
Should you wish to apply any Technical Clarification for legacy rating tools to your projects, please submit a Technical Question to the NZGBC to
explain why and how it applies. You can access the online Technical Question form here
| Technical Question Title | Tool Version | Date Released | Credit Name | Sub-credit Name | TC Link |
|---|---|---|---|---|---|
| Compliance using Time Clock Methodology | DABv1 | April 2021 | 26 - Light Pollution | Light Pollution to Neighbouring Bodies | Link |
|
Approved Ruling: To demonstrate compliance with the credit criteria for the Light Pollution to Neighbouring Bodies and/or Light Pollution to Night Sky, projects using a time clock methodology must ensure that all the relevant building lights are commissioned to ensure that the lights are operating as designed. Evidence of commissioning must be submitted as part of the Green Star assessment. For the purposes of the credit criteria Building Commissioning, all building lights, including those installed with a time clock, fall within the definition of 'nominated building systems'. |
|||||