 Green Star Technical Clarification Rulings

Technical Clarifications for Green Star represent our answers to Technical Questions submitted by projects, and provide further guidance and reference to others. The list is regularly updated.  

There are two types of Technical Clarifications listed in the table below:

General Clarifications

These are extensions to the guidance provided in the Submission Guidelines. They clarify and sometimes supersede the original Credit Criteria or 
Compliance Requirements. General Clarifications set precedent for future project teams to follow. Should a project team wish to apply a general clarification to its project, there is no requirement for further Technical Questions to be submitted. NZGBC Assessors will also use them as precedents to assess submissions.

Project Specific Clarifications

These are published as references for other projects but, unlike General Clarifications, they do not set precedent. They often relate to special 
situations where multiple prerequisites exist for a particular project and are less likely to reoccur to another project. Therefore, rulings set for Project Specific Clarifications are often conditional and will likely vary for other projects. Each project still needs to submit its own Technical Questions and provides evidence relating to its own building in order to have a similar ruling approved for that specific building. 

Should you wish to apply any Technical Clarification for legacy rating tools to your projects, please submit a Technical Question to the NZGBC to 
explain why and how it applies. You can access the online Technical Question form here

Technical Question Title Tool Version Date Released Credit Name Sub-credit Name TC Link
ASHRAE Standard 55-2013 -or - 55-2020 : Applicability DABv1, DABv1.1 January 2023 14 - Thermal Comfort Thermal Comfort
Approved Ruling:

The Submission Guideline references the ASHRAE Standard 55-2013 (55-2020 may also be used) for naturally ventilated spaces. The ASHRAE standard 55-2020 Applicability section 5.4.1 states that this method may be used only when (a) no heating system is operating, and (d) when the prevailing mean outdoor temperature is greater than 10°C. The Submission Guidelines section 14.1.1 suggests that spaces may contain heating, which is counter to the ASHRAE Standard.

Where projects are not in accordance with the methodology outlined in ASHRAE 55-2020 Section 5.4.1(a) and section 5.4.1(d), due to having an operating heating system and prevailing mean outdoor temperatures lower than 10°C which falls outside the applicability limits of the methodology. The winter discomfort or underheating should be assessed through the Predicted Mean Vote (PMV) methodology in accordance with the requirements outlined in 14.1.2 of the Design & As Built Submission Guidelines.

Summer discomfort and overheating can still be assessed using the adaptive comfort methodology outlined in ASHRAE – 55 provided all relevant applicability limits are met i.e a combination of assessment methods acceptable with PMV used during the heating season and adaptive comfort model approach used for the remainder of the year.